logo
Aperçu ProduitsCapteur oxygène-gaz

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices
YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Image Grand :  YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Détails sur le produit:
Lieu d'origine: Grande-Bretagne
Nom de marque: YJJ
Numéro de modèle: O2-C2
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Palettisé
Délai de livraison: 5-8 jours
Conditions de paiement: L / C, D / A, D / P, T / T, Western Union, Moneygram
Capacité d'approvisionnement: 2200

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

description de
Plage de mesure: 0 - 30% de concentration en oxygène Sortie actuelle: 80 à 120 μA
Résistance à la charge: 47 - 100 ohms Temps de réponse: T90 (de 20,9% à 0%) <45 secondes
Température de fonctionnement: -30 à 55℃ Plage d'humidité: 5 - 95% Rh
Plage de pression: 80 à 120 KPa Taille: 20,3 × 23 mm
Mettre en évidence:

electrochemical oxygen sensor 0-30% range

,

oxygen alarm device sensor

,

YJJ O2-C2 oxygen sensor

Product Description:

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

 

Features:

Main parameters of the O2-C2 oxygen sensor are as follows:

Measurement range

0 - 30% oxygen concentration

Output signal

Current output: 80 - 120 μA (at 22℃, 20.9% oxygen)

Load resistance: 47 - 100 ohms

Response time

T90 (from 20.9% to 0%) < 45 seconds

Environmental adaptability

Operating temperature: -30 to 55℃

Humidity range: 5 - 95% RH

Pressure range: 80 - 120 kPa

Other features

Size: Φ20.3 × 23mm

Weight: < 18g

Storage period: 6 months (sealed preservation)

Linear error: ±0.6% of the full range

Application fields: Oxygen alarm device, atmosphere analyzer

 

Specifications:

Range 0 - 30 ppm
Sensitivity 1.9 ± 0.8 μA/ppm (at 20℃)
Baseline range -0.2 to 2.5 μA (@20℃)
Response time ≤ 45seconds (T90)

 

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices 0

Coordonnées
ShenzhenYijiajie Electronic Co., Ltd.

Personne à contacter: Miss. Xu

Téléphone: 86+13352990255

Envoyez votre demande directement à nous (0 / 3000)