Détails sur le produit:
|
| Résolution: | 0,01% (0 - 5% vol) | Précision: | ± 50 ppm ± 5% de valeur vraie |
|---|---|---|---|
| Temps de préchauffage: | 60 secondes | Temps de réponse (T90): | ≤ 30 secondes |
| Répétabilité de point zéro: | ± 2% FSD | Répétabilité de sensibilité: | ± 2% FSD |
| Dérive à long terme: | ± 1% de FSD | Température de travail: | -20 - 60 ℃ |
| Mettre en évidence: | ethylene infrared gas sensor,IRS7 gas sensor with selectable range,0-2000ppm ethylene gas detector |
||
Product Description: YJJ IRS7 0-2000PPM Series Ethylene Infrared Gas Sensor (With Selectable Range) Features: Main features Low power consumption Compact size, easy installation Complete factory calibration Excellent long-term stability Digital output Linear voltage output Excellent temperature performance Dual-channel design Robust metal structure Overview IR-S is a gas sensor based on the principle of infrared absorption. Compared with traditional gas sensors, it has the
Personne à contacter: Miss. Xu
Téléphone: 86+13352990255