logo
Aperçu ProduitsCapteur de gaz

YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor
YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

Image Grand :  YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

Détails sur le produit:
Lieu d'origine: CHINE
Nom de marque: YJJ
Numéro de modèle: MP801
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Pack de boîtes
Délai de livraison: 5-8 jours
Conditions de paiement: L / C, D / A, D / P, T / T, Western Union, Moneygram
Capacité d'approvisionnement: 2200

YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

description de
Résistance à la charge: RL réglable Caractéristiques des éléments sensibles au gaz: Résistance au chauffage RH: 95Ω ± 10Ω (à température ambiante
Sensibilité: Rs (dans 10 ppm alcool) ≥ 2 Pente de concentration: α≤ 0,6 (R50PPM / R10PPM pour l'alcool)
Conditions de test standard: 20 ℃ ± 2 ℃; Humidité: 65% ± 5% Rh Temps d'échauffement: 48 heures
Mettre en évidence:

MOS air quality sensor 0.5-1000PPM

,

metal oxide semiconductor gas sensor

,

YJJ MP801 air quality detector

Product Description:

YJJ MP801 0.5 - 1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor

 

Features:

MP801 is a metal oxide semiconductor (MOS) air quality sensor, sensitive to benzene, toluene, formaldehyde, alcohol and smoke. Its typical detection range is 0.5 - 1000 ppm (measured by alcohol), and the standard test conditions are 20 ± 2 ℃, 65 ± 5% RH, with a preheating time of ≥ 48 hours.

 

Parameters Symbol / Unit Typical Value / Range Remarks

Detected Gas — Benzoic acid, Toluene, Formaldehyde, Alcohol, Smoke Non-selective, sensitive to multiple VOCs and smoke

Detection Range ppm 0.5 - 1000 (Alcohol) Data is based on alcohol as the reference, other gases need calibration

Loop Voltage Vc ≤ 24 V DC Standard test Vc = 5.0 ± 0.1 V

Heating Voltage Vh 5.0 ± 0.1 V AC/DC Requires stable power supply to ensure consistency

Load Resistance Rl Adjustable By voltage division to convert resistance change into voltage output

Heating Resistance Rh 95 ± 10 Ω (room temperature) From actual measurement, it varies between approximately 85 - 130 Ω for different batches, refer to actual measurement / batch specifications

Heating Power Consumption Ph ≤ 300 mW Other data also show ≤ 240 mW, it is a batch difference

Sensitive Body Resistance Rs 1 kΩ - 15 kΩ (10 ppm Alcohol) Changes with gas type / concentration

Sensitivity S ≥ 2 (10 ppm Alcohol) S = Rs (air) / Rs (10 ppm Alcohol)

Concentration Slope α ≤ 0.6 (Alcohol) α = R (50 ppm) / R (10 ppm), reflects linearity

Standard Test Conditions — T = 20 ± 2 ℃; RH = 65 ± 5%; Vc = 5.0 ± 0.1 V; Vh = 5.0 ± 0.1 V Data is based on these conditions

Preheating Time — ≥ 48 hours New parts / after long storage require sufficient preheating

Package / Pin — Metal, DIP-4 1/2 pin for heating; 3/4 pin for measurement

Working Principle — Metal Oxide Semiconductor (MOS) Resistance increases with the concentration of the target gas

Selection and Usage Tips

Detection Range and Sensitivity: 0.5 - 1000 ppm based on alcohol as the reference; S ≥ 2 at 10 ppm alcohol is the benchmark, actual calibration is required based on the target gas and concentration range.

Power Supply and Heating: Loop Voltage ≤ 24 V DC; Heating Vh = 5.0 ± 0.1 V (AC/DC); Heating Resistance Rh ≈ 95 ± 10 Ω, Power Consumption ≤ 300 mW (data shows ≤ 240 mW), refer to actual measurement / batch specifications.

Load Resistance Rl: Adjustable voltage division to obtain voltage output; Rl affects sensitivity and linearity, need to optimize matching with the target gas.

Environment and Stability: Standard test 20 ± 2 ℃, 65 ± 5% RH; For long-term storage, recommend - 20 to + 60 ℃, dry sealed; Avoid high concentration gas, silicon vapor and water condensation before powering on.

Preheating and Aging: New parts or after long storage, preheat ≥ 48 hours; The aging time for storage should be extended accordingly for longer storage periods.

Non-selective and Cross-Sensitivity: Responds to benzene, toluene, formaldehyde, alcohol, and smoke; Need to evaluate interference in the target scenario and calibrate.

Data Variations Explanation

Heating Power Consumption: Mainstream data is ≤ 300 mW, also described as ≤ 240 mW, it is a batch / version difference, refer to actual measurement and batch specifications.

Heating Resistance: Commonly about 95 ± 10 Ω, some data 85 - 130 Ω, recommend designing bias based on batch actual measurement.

 

Specifications:

 

Parameter Details Parameter
Model MP801 Model
Sensor Type Semiconductor Flat-Surfaced Gas Sensor Sensor Type
Standard Package Metal Cap Standard Package
Heater Voltage Vh 5.0 ± 0.1 V (AC/DC)
Load Resistance Rₗ Adjustable

 

YJJ MP801 0.5-1000PPM Metal Oxide Semiconductor (MOS) Air Quality Sensor 0

Coordonnées
ShenzhenYijiajie Electronic Co., Ltd.

Personne à contacter: Miss. Xu

Téléphone: 86+13352990255

Envoyez votre demande directement à nous (0 / 3000)