logo
Aperçu ProduitsCapteur oxygène-gaz

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration
YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Image Grand :  YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

Détails sur le produit:
Lieu d'origine: Grande-Bretagne
Nom de marque: YJJ
Numéro de modèle: 4OXV AAY80-390-CN 4OX-V
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Palettisé
Délai de livraison: 5-8 jours
Conditions de paiement: L / C, D / A, D / P, T / T, Western Union, Moneygram
Capacité d'approvisionnement: 2200

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

description de
Principe de fonctionnement‌: Principe électrochimique Plage de mesure‌: 1 à 25% vol. O₂
‌Surcharge maximale‌: 30% vol. O₂ ‌Autput Signal‌: 00,10 ± 0,02 mA dans l'air
‌Temps de réponse (T90)‌: <15 secondes Courant zéro (biais)‌: < 0,6% vol. O₂
Linéarité: Généralement considéré comme linéaire dans la plupart des cas Température de fonctionnement‌: -20 ° C à + 50 ° C
Mettre en évidence:

electrochemical oxygen sensor 0-30% range

,

oxygen gas sensor ambient measurement

,

YJJ 4OXV oxygen sensor with warranty

Product Description:

YJJ 4OXV AAY80-390-CN 4OX-V 0-30% Electrochemical Oxygen Sensor Measures Ambient Oxygen Concentration

 

Features:

Oxygen sensor 4OXV technical parameters

measurement

How it works: electrochemistry

Measurement range: 1-25% O2

Maximum overrun range: 30%

Signal output: 0.1 0.02mA

Response time (T90) : < 15s

Zero drift: < 0.6% O2

-ity: many cases can be regarded as -, see the specific data

 

Electrical parameters

Load resistance: 100 Ω

 

The mechanical parameters

Weight: < 16g

Shell material: ABS

 

Using the environment

Use temperature: - 20 to 50 ℃

Temperature: 0-20 ℃

Thermal transient: < 23.5% O2

Pressure: atmospheric pressure 20%

Pressure coefficient: < 0.02%/mBar

Pressure transient: < 200% signal change

Humidity: 5-95%RH non-condensing, short term up to 0-99% non-condensing

 

life

Long-term sensitivity drift: < 2%/ month

< 5%/ year typical value

Use time: 2 years

Storage time: 6 months

 

Specifications:

Load resistance 100 Ω
Maximum overrun range 30%
Signal output 0.1 0.02mA
Zero drift < 0.6% O2
Load resistance 100 Ω

 