logo
Aperçu ProduitsCapteur de gaz

NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane Propane

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane Propane

NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane
NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane

Image Grand :  NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane Propane

Détails sur le produit:
Lieu d'origine: JAPON
Numéro de modèle: NAP-57S
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Boîte en papier
Délai de livraison: 3-5 jours ouvrables
Conditions de paiement: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacité d'approvisionnement: 5000 pièces

NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane Propane

description de
Temps de réponse (T90): < 10 secondes Temps de récupération (T10): < 30 secondes
Température de fonctionnement: -10°C à +50°C Humidité opérationnelle: 15 % - 90 % HR
Vie opérationnelle attendue: > 24 mois
Mettre en évidence:

combustible gas sensor with good stability

,

methane propane gas detector

,

contact combustion gas sensor

 

            NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane Propane

 

 

Key Features:

  1. Bias - free Design: It operates without the need for bias voltage, which simplifies the circuit design of the supporting detection equipment and reduces the integration difficulty for developers of portable and fixed gas detectors.
  2. Stable Performance: The long - term output drift is less than 20% per year, and it has good repeatability. This ensures that the sensor can provide reliable and consistent detection data during long - term use.
  3. Wide Environmental Adaptability: It can work normally in the temperature range of - 40 ℃ to + 50 ℃ and the humidity range of 15% - 90% RH. It is also adaptable to the pressure fluctuation between 800 - 1200 mbar, making it suitable for various harsh working environments.
  4. Standard Packaging: Adopting the industry - standard 4 - series packaging and 3 - pin interface, it is convenient to replace like - type sensors, which is conducive to the maintenance and upgrading of equipment.

Typical Applications:

  1. Industrial Safety: It can be installed in chemical plants, fertilizer factories and other places where ammonia is produced or used. It monitors ammonia concentration in real time to prevent safety accidents such as poisoning caused by excessive ammonia leakage.
  2. Food & Beverage Industry: Ammonia is often involved in some food processing links or used for refrigeration. The sensor can monitor ammonia leakage in refrigeration systems and production workshops to ensure food safety and the health of employees.
  3. HVAC and Refrigeration Systems: It is used to detect ammonia gas leakage in ammonia - based refrigeration equipment of central air - conditioning and cold storage, so as to avoid equipment failure and environmental pollution caused by leakage.
  4. Portable/A stationary Gas Detectors: Due to its compact size and simple electrical requirements, it is an ideal core component for handheld portable ammonia detectors and fixed ammonia concentration monitoring terminals used in confined spaces.

 

Measurement Range 0 - 100 ppm
Maximum Overload 200 ppm
Output Signal/Sensitivity 100 ± 30 nA/ppm
Typical Baseline Range (Pure Air) ± 1 ppm NH3 equivalent
Response Time (T90) < 40 seconds
Repeatability ± 10 %
Long - term Output Drift < 20 % per annum
Recommended Load Resistor 10 ohms
Bias Voltage 0 V (no bias required)
Operating Temperature - 40 ℃ to + 50 ℃
Operating Pressure 800 - 1200 mbar
Operating Humidity 15 % - 90 % RH
Expected Operating Life > 24 months
Storage Temperature 0 - 20 ℃
Maximum Open - Circuit Voltage 1.3 V
Maximum Short - Circuit Current < 1 A
Maximum Current at 2000 ppm < 0.3 mA
Package Format 4 - series with 3 - pin interface

 

NAP-57S Contact Combustion Gas Sensor Good Stability for Detecting Combustible Gases Like Methane  Propane 0

Coordonnées
ShenzhenYijiajie Electronic Co., Ltd.

Personne à contacter: Miss. Xu

Téléphone: 86+13352990255

Envoyez votre demande directement à nous (0 / 3000)