HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection
HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Image Grand :  HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

Détails sur le produit:
Lieu d'origine: ROYAUME-UNI
Nom de marque: Alphasense
Numéro de modèle: hcn-a1
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Forfait standard
Délai de livraison: 3-5 jours de travail
Conditions de paiement: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacité d'approvisionnement: 10000 pièces/mois

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

description de
Plage de mesure: 100 ppm Sensibilité: 30ppm
Courant de point zéro: <±2 ppm Résolution: <0,05ppm
Mettre en évidence:

hydrogen cyanide gas sensor

,

chemical leak detection sensor

,

HCN-A1 gas sensor

HCN-A1 Hydrogen Cyanide Gas Sensor Used For Chemical Leak Detection

 

The HCN-A1 electrochemical hydrogen cyanide gas sensor is commonly used in chemical leak detection, environmental monitoring, and other applications.

 

Physical and usage cycle parameters

Dimensions Diameter 20.2mm, Overall height 16.5mm (including label), Dimensional tolerance ±0.15mm
Weight <6 grams
Operating life Output signal drops to 80% of initial value in over 12 months, official 12-month warranty
Storage period 6 months in a sealed environment at 3-20℃

 

Environment adaptation parameters

Operating temperature -30~50°C; sensitivity at -20°C is 75-95% of that at 20°C, and sensitivity at 50°C is 105-120% of that at 20°C.
Operating humidity 15-90% RH (continuous operation)
Operating pressure 80-120 kPa
Temperature effect on zero point zero-point change relative to 20°C at -20°C < 0-1 ppm; zero-point change relative to 20°C at 50°C < ±1 ppm.

 

Electrical and interference related parameters

Recommended load resistor 10 - 33Ω
Bias requirement No additional bias voltage required

 