logo
Aperçu ProduitsCapteur de gaz

TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode
TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

Image Grand :  TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

Détails sur le produit:
Lieu d'origine: Japon
Nom de marque: Figaro
Numéro de modèle: TGS4260
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: FORFAIT STANDARD
Délai de livraison: 3-5 jours de travail
Conditions de paiement: LC, D/A, D/P, T/T, Western Union
Capacité d'approvisionnement: 10000 pièces/mois

TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

description de
Gaz détecté: Oxygène (O2) Principe de détection: Électrolytique à potentiel constant
Plage de mesure: 0 – 25 vol.% Surcharge: Max. 30 vol.%
Mettre en évidence:

oxygen gas sensor potentiostatic electrolysis

,

three electrode oxygen sensor

,

TGS4260 gas sensor with warranty

TGS4260 Oxygen Gas Sensor Potentiostatic Electrolysis Type Three Electrode

 

Constant-Potential Electrolytic, Lead-Free Oxygen (O₂) Sensor — Industry-Standard 20mm Package, Long Lifespan, Linear Output

 

Features and Applications
1. Lead-free design, RoHS compliant
2. 20mm industry-standard size
3. Linear output, rapid response, high selectivity
4. Shock-resistant, long lifespan


Applications: Portable/fixed oxygen detectors, multi-gas alarms, industrial oxygen concentration monitoring

 

Specification:

Sensitivity Approx. 0.4 mA/vol.% (@ 20.9% O₂, 20 Ω load)
Response Time (T90) < 8 seconds
Resolution 0.1 vol.%
Repeatability ±2%
Bias Voltage -600 mV ±10 mV

Recommended Load Resistance

20 Ω

 

Operating Temperature:

Operating Humidity 15% – 85% RH (non-condensing)
Operating Pressure 100 kPa ±20 kPa
Dimensions Φ20.4 mm × 20.6 mm (including pins)
Weight Approx. 6.0 g
Lifespan > 5 years (in air)
Storage Temperature 5°C – 35°C
Warm-up Time ≥ 3 hours

 