4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical

4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical
4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical 4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical 4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical 4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical

Image Grand :  4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: YJJ
Numéro de modèle: 4HCN
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Boîte standard
Délai de livraison: 3-5 jours de travail
Conditions de paiement: LC, D/A, D/P, T/T, Western Union
Capacité d'approvisionnement: 1000 pièces/mois

4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical

description de
Gamme: 0 à 50 ppm Surcharge maximale: 100 ppm
Sensibilité: 0.10 ± 0,02 μA/ppm Réponse T90: ≤120 s
Mettre en évidence:

HCN gas sensor electrochemical

,

hydrogen cyanide sensor 3-electrode

,

gas detector with warranty

4HCN CLE‑0731‑4000 Hydrogen Cyanide (HCN) Gas Sensor 3-Electrode Electrochemical

 

Application Scenarios
* Electroplating, metallurgy, gold mining (cyanide processes)
* Chemical, pharmaceutical, synthetic fiber
* Flue gas/incinerators, laboratory fume hoods
* Portable/fixed HCN detectors, safety instrumented systems


Selection Recommendations
* Regular occupational exposure (≤10 ppm): Select 4HCN-10S
* Industrial leakage/high concentration: Select 4HCN-50S
* Replace CITY 4HN: Direct pin compatibility, 0 mV bias, no circuit modification required

 

Specification:

Resolution 0.1 ppm
Bias Voltage 0 mV (No polarization required)
Measurement Range 0–50 ppm
Sensitivity 0.065 ± 0.020 μA/ppm
T90 Response ≤105 s
Baseline < ±0.2 μA
Resolution 0.2 ppm
Bias Voltage 0 mV

 