logo
Aperçu ProduitsCapteur de gaz

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring

Certificat
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
LA CHINE ShenzhenYijiajie Electronic Co., Ltd. certifications
Je suis en ligne une discussion en ligne

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring
YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring

Image Grand :  YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring

Détails sur le produit:
Lieu d'origine: Chine
Nom de marque: YJJ
Numéro de modèle: ZE03-NO2
Conditions de paiement et expédition:
Quantité de commande min: 1
Prix: Négociable
Détails d'emballage: Pack de boîtes
Délai de livraison: 5-8 jours
Conditions de paiement: LC, D/A, D/P, T/T, Western Union, MoneyGram
Capacité d'approvisionnement: 1500

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring

description de
Plage de mesure: 0 - 20 ppm Résolution: 0,01 ppm
Limite de détection: ≤ 0,05 ppm T90 Temps de réponse: ≤ 30 secondes
Tension d'alimentation: C.C 5,0 V ± 0,1 V Courant de fonctionnement: < 5 mois
Signal de sortie: 1. Port série TTL UART Tension analogique: 0,4 - 2,0 V
Mettre en évidence:

YJJ ZE03-NO2 NO2 gas sensor module

,

electrochemical NO2 sensor 0-20ppm

,

air quality monitoring NO2 sensor

Product Description:

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm for Atmospheric Air Quality Monitoring

 

Features:

I. Basic Information

Model: ZE03-NO2

Gas: NO₂ - Nitrogen Dioxide

Principle: Three-electrode electrochemical integrated module (sensor + amplification circuit + temperature compensation + calibration program)

Shape: Φ23.3 × 31.2mm, straight insertion with three-pin terminals

II. Core Electrical Parameters (25℃) Table

Project Technical Parameters

Measurement Range: 0 - 20 ppm

Resolution: 0.01 ppm

Detection Lower Limit: ≤ 0.05 ppm

T90 Response Time: ≤ 30 s

Power Supply Voltage: DC 5.0V ± 0.1V

Operating Current: < 5 mA (Low Power Consumption) Winsen

Output Signal: 1. TTL Serial Port UART (9600 baud)

2. Analog Voltage: 0.4 - 2.0V

Operating Temperature: -20℃ - +50℃

Humidity Conditions: 15% - 90% RH, No Condensation

Service Life: ≥ 24 Months

Zero Point Drift: Small, Suitable for Long-Term Continuous Online Monitoring

III. Product Features

Integrated Factory Calibration, No Need to Build Amplifier Circuit, Power On Direct Reading of Concentration Value, Shortens Development Cycle;

Three Electrode Structure, Effectively Suppresses Cross-Interference of Ozone, Sulfur Dioxide, etc.;

Built-in Temperature Compensation Circuit, Small Temperature Drift, Stable Measurement in Outdoor Environment;

Digital + Analog Dual Output, Compatible with Single-Chip Microcontrollers, Transmitter Board Development;

Compact Size, Suitable for In-Building Installation in Small Instruments, Resistant to Moisture and Not Easily Poisoned Zhengzhou Winsen Electronics Technology Co., Ltd.

IV. Main Applications

1. Atmospheric Air Quality Monitoring (Main Application)

Micro-grid Air Station, Urban Road Exhaust Monitoring Equipment;

Air Quality Online Monitoring Terminal for Residential Areas, Factories, Parks;

Long-Term Sampling Record of Indoor and Outdoor NO₂ Air Pollution.

2. Industrial Gas and Exhaust Detection

Simple Detection of Nitrogen Oxides in Boilers, Internal Combustion Engines, Diesel Exhaust;

NO₂ Toxic Exhaust Leakage Monitoring in Smelting, Chemical Industry, Nitric Acid Workshop;

Unorganized Emission Gas Inspection of Polluting Enterprises.

3. Industrial Safety Protection

Alarm Probe for Nitrogen Dioxide Leakage in Chemical Workshops;

Motor Vehicle Exhaust Monitoring in Tunnels, Underground Garages;

Detection of Nitric Acid Volatile Gas Concentration in Laboratories.

4. OEM Instrument Accessories

Portable Multi-Parameter Gas Detector;

Fixed NO₂ Gas Transmitter;

Atmospheric Sampling Analyzer, Environmental Monitoring Internet of Things Module.

 

Specifications:

Detection gas NO2
Size Φ23.3 × 31.2 mm
Power supply DC 5V
Measurement range 0 - 20 ppm
Operating temperature -30°C to +55°C

 

YJJ ZE03-NO2 Electrochemical NO2 Gas Sensor Module 0-20ppm Atmospheric Air Quality Monitoring 0

 

Coordonnées
ShenzhenYijiajie Electronic Co., Ltd.

Personne à contacter: Miss. Xu

Téléphone: 86+13352990255

Envoyez votre demande directement à nous (0 / 3000)